Unused flat roof, Underground concrete, sealed with high polymer, with ballast
- Gravel
- Separation and protection layer
- High polymer seal
- GLAPOR flex hot bitumen
- GLAPOR cellular glass boards
- GLAPOR flex hot bitumen
- Bitumen primer
- Concrete ceiling
Description of the application
The GLAPOR flat roof is a compact and under flow secured bonded flat roof construction.
The thermal insulation is installed free of thermal bridges using GLAPOR flex hot bitumen or GLAPOR k-2k cold adhesive on the entire substructure.
The sealing system is conform to the legal regulations and standards for respective intended use.
The minimum roof pitch of the flat roof construction of 2.0% should be kept. The GLAPOR gradient system has different slopes available.
To avoid concentrated drainage GLAPOR roof riders are available in different versions.
Planning notes / Execution notes
A vapor barrier is not required when using GLAPOR cellular glass insulations because GLAPOR cellular glass boards are vapor-tight.
The underground should be level, gem. DIN 18 202, designed to be load bearing and dry and free from residues (oil, grease, etc).
10 kN / m² can be assumed without proof for the wind resistance of fully glued roof systems with GLAPOR foam glass and GLAPOR flex hot bitumen.
Fire protection “Hard roffing” according to DIN 4102-7 – Cellular glass panels belong to building material class A1. The thermal insulation is not flammable. For the component “roof”, the state building regulations require, in addition to the classification in a building material class (A1) usually a so-called “hard roofing”. This is to ensure that the roof structures are resistant to spreading fire and radiant heat. For the manufacturers of waterproofing systems, these tests with the different seals are available.
Verarbeitungshinweise
Clean surface and prime with bitumen primer / bitumen emulsion and allow drying in air.
Consumption: approx. 0.3 kg / m²
Install GLAPOR cellular glass panels in mitre.
Pour flex hot bitumen.
Dip the insulation boards with two sides into the adhesive and insert diagonally so that the longitudinal and transverse joints are filled with bitumen.
For a short time, secure the insulation board against movement.
Depending on the evennes of the ground.
Consumption: 5 to 8 kg / m²
Pour GLAPOR flex hot bitumen and spread with a rubber spatula on the cellular glass surface.
Top coat with GLAPOR flex hot bitumen.
Consumption approx. 2.0 kg / m²
Variant with a high polymer seal.
Please note the instructions of the manufacturer.
Other sealing systems on request.
Then distribution of gravel.